ANALISIS PERBANDINGAN DAYA DUKUNG PONDASI TIANG PANCANG BERDASAR HASIL UJI SPT DAN PENGUJIAN DINAMIS

Hinawan Teguh Santoso, Juandra Hartono

Abstract

The foundation work is one of the main works in bridge construction. Failure of the foundation will be fatal for the entire bridge construction. Therefore, it is necessary to test the bearing capacity of the pile to determine the installed foundation capacity. The most accurate and most expensive method for determining the bearing capacity of a pile is a static load test, which is a full-scale trial method of giving a load 2 or 3 times greater than the designed load. Another method that is more economical and entirely accurate is using the High Strain Dynamics Pile Test (HSDPT) or often called the Pile Driving Analyzer (PDA) Test. This PDA test took a sample of 18 points of 600 mm diameter pre-stressed concrete piles on the Kaligawe Bridge located on Jalan Kaligawe KM 2+350, Semarang, Central Java. Based on the core drilling results, the soil layer was dominated by clay with an N-SPT value < 30 to a depth of 45 meters. The average bearing capacity of PDA test results is 432.4 tons or 0.4% greater when compared to the empirical approach based on N-SPT value (430.7 tons). The bearing capacity of the CAPWAP analysis is 401.0 tons or 7.3% less when compared to the PDA test, because the PDA test results are further processed using Signal Matching Analysis (SMA). CAPWAP analysis shows that the bearing capacity of piles is dominated by friction resistance by 71.7% and end resistance by 28.3% or by 4.4% difference when compared to the empirical approach, where the friction resistance value is 67.3% and end resistance is 32.7%. In general, it can be said that the PDA test is reliable enough to confirm the bearing capacity of the pile foundation that has been installed in the field.

Full Text:

PDF

References

Bachtiar, V. (2012). “Evaluasi Daya Dukung Tiang Pancang Berdasarkan Data Cone Penetration Test (CPT) dan Pile Driven Analyzer (PDA) pada Tanah Lunak di Kota Pontianak”. Jurnal Teknik Sipil Untan, Vol.12 No.1, 107-116.

ASTM. (2017). “D4945-17: Standard Test Method for High-Strain Dynamic Testing of Deep Foundation”. USA: ASTM International.

CV. Feldspar Geotechnical Engineering. (2018). “Laporan Penyelidikan Geoteknik (Pemboran) di Jembatan Kaligawe, Semarang”. Blora.

Das, B.M. (2016). “Principles of Foundation Engineering, Eight Edition”. USA: Cengage Learning.

Haryanto, B., Widiastuti, M., dan Bariah, S.F. (2019). Änalisis Kapasitas Daya Dukung Fondasi Tiang Berdasarkan Data Uji Laboratorium, Uji SPT dan Uji Kalendering pada Proyek Jalan Pendekat Jembatan Mahakam IV Sisi Samarinda Kota”, Jurnal Teknologi Sipil, Vol.3 No.1, 8-15

Khomsiati, N.L., Jirna, I.W., dan Setyawan, E. (2019). “Perbandingan Daya Dukung Aksial Pondasi Tiang Bor Tunggal Menggunakan Dta Standard Penetration Test (SPT) dan Pile Driving Alaizer (PDA) Test pada Proyek Pembangunaan Jalan Tol Pandaan Malang”. Jurnal Bangunan, Vo. 24 No.1 Maret 2019, 25-32.

Lailaningrum, S.R., Surjandari, N.S., dan Purwana, Y.M. (2014). “Perbandingan Kapasitas Daya Dukung Pondasi Minipile Dengan Rumus Statis, Hasil Uji SPT, dan Hasil Uji PDA”. E-Jurnal Matriks Teknik Sipil, 369-376.

Maizir, H., Jingga, H., dan Toni, N. 2015. “Evaluasi Daya Dukung Tiang Pancang Berdasarkan Metode Dinamik”. Annual Civil Engineering Seminar 2015, Pekanbaru, halaman 221-226.

Nji, L.T. 2012. “PDA Test”. https://lauwtjunnji.weebly.com /pda-test.html.Diakses pada 5 Februari 2020].

PPK 3.6 Provinsi Jawa Tengah. (2019). “Shop Drawing Paket Penggantian Jembatan Kaligawe, Cs”. Semarang.

PT. Arcon Indonesia. (2017). “Technical Data For: DD Series Guide Rod Diesel Pile Hammers”. http://www.arcon-indo.com.

PT. Geo-Pondasi Testing. (2019). “Laporan PDA Paket Penggantian Jembatan Kaligawe”. Tangerang.

PT. WIKA Beton. (2017). “Company Profile-The Precast Concrete Manufacturer”. Jakarta.

Putri, M.S., Apriyanti, Y., dan Fahriani, F. (2018). “Analisis Perbandingan Daya Dukung dan Penurunan Tiang Pancang Tunggal Dengan Metode Statik dan Uji Beban”. Prosiding Seminar Nasional Penelitian dan Pengabdian Masyarakat, Pangkal Pinang, 2 Oktober 2018.

Randyanto, E.S., Sumampow, J.E., dan Balamba, S. (2015). “Analisis Daya Dukung Tiang Pancang dengan Menggunakan Metode Statik dan Calendering Studi Kasus: Proyek Pembangunan Manado Town Square 3”. Jurnal Sipil Statik Vol.3 No.9, 631-643.

Yusa, M., dan Nugroho, S.A. (2007). “Korelasi Penentuan Daya Dukung Tiang Cara Empirik (CPT) dengan Pile Driven Analysis (PDA) di Kota Pekanbaru”. Jurnal Media Teknik Sipil, Edisi Januari 2017, 41-47.

Yusti, A. dan Fahriani, F. (2013). “Analisis Daya Dukung Pondasi Tiang Pancang Diverifikasi dengan Hasil Uji Pile Driving Analizer Test dan CAPWAP pada Proyek Pembangunan Gedung Kantor Bank Sumsel Babel di Pangkalpinang”. Jurnal Fropil Vol 2 No.1 Januari-Juni 2014, 19-31.

Refbacks

  • There are currently no refbacks.