Penentuan Peak Kilovoltage (kVp) Pesawat Sinar-X Dengan Pemanfaatan Imaging Plate (IP) Di RSUD Dr. Moewardi
Abstract
Research has been carried out to determine the kVp of X-ray aircraft using an imaging plate (IP) as a measuring tool. The imaging plate functions to record images after irradiation and as a detector to capture and store X-ray energy when it penetrates an object. The purpose of this study is to use IP as a kVp measurement tool. The method used is to create a characteristic curve of the relationship between the ratio of Region of Interest (ROI) of two aluminum filters to rated voltage (kVp). From the research obtained the equation y = 2816.61 x2 – 4532.19 x + 1878.65 with R2 = 0.988. The kVp test was carried out using a fluoroscopic X-ray model SM-20HFH. The test results obtained that the measured kVp value at a voltage of 70 kV was 66.21 kV and an error value of 5.41%. While the measured kVp value at 55 kV is 58.95 kV with an error value of -7.18%. These results indicate that IP can be used to measure kVp with an error below the allowable tolerance, namely the max error ≤ of 10%.
Keywords
Full Text:
PDFReferences
- Fajrin, H. R., Rahmat, Z., & Sukwono, D. 2019. Kilovolt Peak Meter Design As A Calibrator Of X-Ray Machine. International Journal of Electrical and Computer Engineering (IJECE), 9(4), 2328-2335.
- Peraturan Kepala Badan Pengawas Tenaga Nuklir No 9. 2011. Keselamatan Radiasi dalam Penggunaan Pesawat Sinar-X Radiologi Diagnostik dan Intervensional. Jakarta: BAPETEN.
- Aryani, A. I., Nugroho, I. K., & Nurcahyo, P. W. 2016. Pengujian Akurasi kVp Dan Linieratias Pada Pesawat Sinar-X di Laboratorium Prodi Diploma III Teknik Radiodiagnostik Dan Radioterapi Purwokerto, Journal Imaging Diagnostik, 2(2), 172- 174.
- Mubarok, M. A., Yulianto., & Indrato, B. 2018. Scintillator X-Ray kV Meter. Seminar Tugas Akhir: Politeknik Kesehatan Kementrian Kesehatan Surabaya.
- Ulgen, Y., & Tumer, M. 2011. Design of a Microcontroller Based and X-Ray Waveform Independent kVp-Meter. American Journal of Biomedical Engineering, 1(1), 41-43.
- Taha, M. T. 2015. Study The Quality Assurance Of Conventional X-Ray Machine Using Non-Invasive KV Meter. International Journal Of Science And Research (IJSR). 4(3). 372-375.
- Sartinah., Sumariyah., & Ayu, N. 2008. Variasi Nilai Eksposi Aturan 15 Persen pada Radiografi Menggunakan Imaging Plate untuk Mendapatkan Kontras Tertinggi. Berkala Fisika, 11(2), 45-52.
- Jannah, N., Armyanah, B., & Abdullah B. 2014. Analisis Kurva Karakteristik Image Plate Computed Radiography (CR) Sebagai Indikator Sensitifitas Terhadap Sinar-X. Prosiding Seminar Nasional Geofisika, 200-206.
- Shetty, C. M., Barthur, A., Kambadakone, A., Narayanan, N., & Kv, Rajagopal. 2011. Computed Radiography Image Artifacts Revisited. American Roentgen Ray Society, 196, 37-47.
Refbacks
- There are currently no refbacks.