Kajian Sistem Penghawaan terhadap Kenyamanan Termal pada Rumah Produksi Tenun Bukan Mesin

Astrihasna Shafa, Gagoek Hardiman, Wahyu Setia Budi

Abstract

Thermal comfort is essential when designing a building that will serve as a work activities place. A comfortable work environment will increase worker productivity. This study is a form of correction to non-machine weaving production house to obtain an optimal ventilation system for achieving thermal comfort. This research uses quantitative in non-machine weaving production house in Pekalongan. The data collected are thermal measurement data and air intensity in the workspace directly from morning to evening for two days. Measurements using a thermometer, hygrometer, and hot wire anemometer. Measurements were carried out in two conditions to compare the air intensity in the workspace. The measurement results will be analyzed using the recommended standards. The observations show that natural ventilation is not optimal in a horizontal building and an open space with an inner court. The fan's type and shape affect the airflow arrangement in the room.

Keywords

ventilation system; thermal comfort; non-machine weaving production house; pekalongan

Full Text:

PDF

References

Azizah, Ronim. (2014). Kajian Kenyamanan Termal pada Rumah Tinggal dengan Model Innercourt. Nalars : Vol 13 No 2. Hlm 73-88.

Badan Standardisasi Nasional. (2001). Tata Cara Perancangan Sistem Ventilasi dan Pengkondisian Udara pada Bangunan Gedung. SNI 03-6572-2001.

Badan Standardisasi Nasional. (2004). Pengukuran Iklim Kerja (Panas) dengan Parameter Indeks Suhu Basah dan Bola. SNI 16-7061-2004.

Binarti, F., Kusuma, H. E., Wonorahardjo, S., & Triyadi, S. (2018). Peranan Unsur-unsur Ruang Terbuka pada Tingkat Kenyamanan Termal Outdoor: Antara Persepsi dan Pengetahuan. Komposisi : Vol 12 No 1. Hlm 41-52.

Dewandaru, A., Budi W. S., & Hardiman, G. (2019). Pengaruh Desain Penghawaan terhadap Kondisi Termal di Gereja Santo Petrus Sambiroto Semarang. Arsitektura: Vol 17 No 2.hlm 231-248.

Hardiman, G. (2012). Pertimbangan Iklim Tropis Lembab dalam Konsep Arsitektur Bangunan Modern. Jurnal Arsitektur, 77-82.

Karyono, T. H. (2013). Arsitektur dan Kota Tropis Dunia Ketiga : Suatu Bahasan tentang Indonesia. Jakarta: Raja Grafindo Persada.

Lippsmeier, G. (1994). Bangunan Tropis. Jakarta: Erlangga.

Menteri Kesehatan Republik Indonesia. (2002). Persyaratan Kesehatan Lingkungan Kerja Perkantoran dan Industri. Permenkes No. 1405/Menkes/SK/XI/2002.

Pamungkas, L. S., & Ikaputra. (2020). Local Wisdom Arsitektur Tradisional dan Kenyamanan Termal Tropis. Arcade: Vol 4 No 2. Hlm160-167.

Razak, H., Gandarum, D. N., Juwana, J. S. (2015). Pengaruh Karakteristik Ventilasi dan Lingkungan terhadap Tingkat Kenyamanan Termal Ruang Kelas SMP di Jakarta Selatan. Agora : Vol 15 No 2. Hlm 1-18.

Rahmayanti. (2020). Pengaruh Window to Wall Ratio terhadap Kenyamanan Fisiologis dengan Menggunakan CFD Ansys 14.Gorontalo : Vol 3 No 1. Hlm 37-43.

Rmiatmoko, D., Setyowati, E., & Hardiman G. (2018). Kontribusi Lubang Angin dan Ventilasi Udara pada Bangunan Sobokarti Semarang dalam Mewujudkan Kenyamanan Termal. Modul : Vol 18 No 2. Hlm 90-96.

Rusyda, H. F. S., Setyowati, E., & Hardiman G. (2018). Kondisi Termal pada Penghawaan Alami di Ruang Tunggu Utama Stasiun Semarang Tawang. Arcade : Vol 2 No 3. Hlm 144-148.

Sari, A. M., Prajnawrdhi, T. A., & Muktiwibowo, A. K. (2020). Tipologi Rumah Sebagai Usaha Berbasis Rumah Tangga (UBR) di Banjar Panti Gede, Kelurahan Pemogan, Denpasar Selatan. SPACE, 221-238.

Soegijanto (1998). Bangunan di Indonesia dengan Iklim Tropis Lembab Ditinjau dari Aspek Fisika Bangunan. Jakarta: Direktorat Jenderal Pendidikan Tinggi Departemen Pendidikan dan Kebudayaan.

Sukma, B. (2017). Pergerakan Udara dan Kenyamanan Termal di Gedung Anggar Samarinda. Universitas Diponegoro: Tesis.

Syamsiyah, N. R., & Izzati, H. N. (2021). Strategi Kenyamanan Termal Masjid (Studi Kasus Masjid Al-Kautsar Kertonatan, Sukoharjo, Jawa Tengah). Langkau Betang: Jurnal Arsitektur. Vol 8 No 2.hlm 98-108.

Refbacks

  • There are currently no refbacks.