Model-Based Evaluation and Optimization of Steam Washing Performance at Darajat Unit 1 Geothermal Power Plant

Iyan Engkuma, Willy Adriansyah, Ali Ashat

Abstract

Steam purity is a critical reliability parameter in geothermal power plants, particularly in steam-dominated systems where impurity carryover may cause turbine deposition, scaling, corrosion, and performance degradation. This study presents a model-based evaluation and optimization of the steam-washing system installed upstream of the separator at Darajat Unit 1 Geothermal Power Plant. The analysis integrates hydraulic droplet sizing, thermodynamic steam-water mixing, and particle-capture modeling through diffusion, interception, and inertial impaction, with particle-size weighting represented using the Rosin-Rammler distribution. The baseline MP343 configuration achieved a predicted steam-washing capture efficiency of 44.54% and a combined reduction efficiency of 40.1% after separator removal, reducing chloride concentration from 0.2167 mg/L to 0.1298 mg/L. First-stage nozzle optimization identified MP375 as the most favorable nozzle at the existing pressure, increasing capture efficiency to 51.73% and combined reduction to 46.6%, although chloride remained above the MHI limit at 0.1158 mg/L. The second-stage optimization evaluated all nozzle configurations at 20 bar. Among these cases, MP375 showed the most favorable predicted performance, achieving 79.89% capture efficiency and 71.9% combined reduction, reducing chloride, iron, silica, and TDS to 0.061, 0.003, 0.003, and 0.149 mg/L, respectively. Field validation is recommended before operational implementation.

Full Text:

PDF

References

  1. I. Richardson, S. Addison, and G. Thompson, “Steam purity considerations in geothermal power generation” in the 35th New Zealand Geothermal Workshop: 2013 Proceedings, vol. 35, 2013.
  2. C. J. Morris, E. K. Mroczek, and T. N. Misa, “Geothermal steam condition performance monitoring,” Geothermics, vol. 81, pp. 101–112, 2019.
  3. R. DiPippo, Geothermal Power Plants: Principles, Applications and Case Studies. Oxford, UK: Elsevier, 2005.
  4. R. Rizaldy, S. J. Zarrouk, and C. Morris, “Liquid Carryover In Geothermal Steam-Water Separators” Proceedings the 38th New Zealand Geothermal Workshop, Auckland, vol. 38., 2016.
  5. P. H. Niknam, L. Talluri, D. Fiaschi, and G. Manfrida, “Gas purification process in a geothermal power plant with total reinjection designed for the Larderello area”. Geothermics, vol. 88, 2020.
  6. V. Chauhan, M. Gudjonsdottir, and G. Saevarsdottir, “Silica scrubbing from superheated steam using aqueous potassium carbonate solution: An experimental investigation”. Geothermics, vol. 80, pp. 1-7, 2019.
  7. H. T. Kim, C. H. Jung, S. N. Oh, and K. W. Lee, “Particle removal efficiency of gravitational wet scrubber considering diffusion, interception, and impaction. Environmental Engineering Science”, vol. 18, no. 2, pp. 125-136, 2001.
  8. J. Pásztor, A. Kakucs, Z. Timár, and E. Egyed-Faluvégi ,“Droplet size analysis of spray nozzles,” Műszaki Tudományos Közlemények, vol. 12, pp. 62-66, 2020.
  9. BETE®, “Spray Nozzles, Fabrications, & Systems Metric Catalog”, 2004.
  10. P. A. Vesilind, “The Rosin-Rammler particle size distribution. Resource Recovery and Conservation”, vol 5 no. 3, pp. 275-277, 1980.
  11. D. Addison and I. Richardson, “Geothermal Steam Turbine Deposition Fundamentals And Proposed Iapws Geothermal Steam Purity Limits”. Proceedings 42nd New Zealand Geothermal Workshop, vol. 42, 2020.
  12. PT. Geoservices Environmental Laboratories, “Certificate of Analysis,” No. GS.COA.07.2021.089, Job No. 21/089, Bandung, Indonesia, 2021
  13. Filters®, “Mesh & Vane Mist Eliminator: Achieving the Potential of Today’s Mist Eliminator. Filters S.p.A.”, Scalenghe, Torino, Italy, 2023
  14. W. Licht, Basic Calculations for Particulate Collection, 2nd ed. New York: Marcel Dekker,1998.

Refbacks