Analysis of the Effect of Inter-Table Shading on Photovoltaic String Performance in a Solar Power Plant Using MATLAB Simulation
Abstract
Shading between adjacent photovoltaic (PV) tables (inter-table shading) is one of the factors that may reduce the output power and performance of PV systems. This study aims to analyze the power response of a PV string to variations in solar irradiance and to evaluate the potential power loss caused by inter-table shading at the Vena Energy Sengkol solar power plant. The research method comprises an analysis of operational data from June to September 2025, shadow geometry calculations, and mathematical modeling in MATLAB and Simulink. The simulation results show that the power of a string consisting of ten modules with a nominal rating of 340 watt peak increases from 0.63 kilowatts at an irradiance of 200 watts per square meter to 3.13 kilowatts at an irradiance of 1000 watts per square meter, while the shading scenario yields a maximum power loss of approximately 8 percent. The cumulative energy analysis shows that AB115 produced 85265.0 kilowatt hours and AB662 produced 83949.6 kilowatt hours; however, this difference in production cannot yet be attributed directly to inter-table shading, so validation using measured data and a more representative PV electrical model is required.
Keywords
Full Text:
PDFReferences
[1] M. Ahmed, I. Harbi, R. Kennel, and M. Abdelrahem, “Maximum power point tracking implementation under partial shading conditions using low-cost photovoltaic emulator,” Eng, vol. 3, no. 4, pp. 424–438, 2022, doi: 10.3390/eng3040031.
[2] C. Ma et al., “Space optimization of utility-scale photovoltaic power plants considering the impact of inter-row shading,” Appl. Energy, vol. 370, no. June, p. 123591, 2024, doi: 10.1016/j.apenergy.2024.123591.
[3] N. Varga and M. J. Mayer, “Model-based analysis of shading losses in ground-mounted photovoltaic power plants,” Sol. Energy, vol. 216, no. January, pp. 428–438, 2021, doi: 10.1016/j.solener.2021.01.047.
[4] R. Alik, A. Jusoh, and T. Sutikno, “A study of shading effect on photovoltaic modules with proposed p & o checking algorithm,” Int. J. Electr. Comput. Eng., vol. 7, no. 1, pp. 29–40, 2017, doi: 10.11591/ijece.v7i1.pp29-40.
[5] M. Silva, J. J. Roberts, and P. O. Prado, “Calculation of the shading factors for solar modules with matlab,” Energies, vol. 14, no. 15, 2021, doi: 10.3390/en14154713.
[6] J. Jamal, I. Mansur, A. Rasid, M. Mulyadi, M. Dihyah Marwan, and M. Marwan, “Evaluating the shading effect of photovoltaic panels to optimize the performance ratio of a solar power system,” Results Eng., vol. 21, no. February, p. 101878, 2024, doi: 10.1016/j.rineng.2024.101878.
[7] A. Livera et al., “Data processing and quality verification for improved photovoltaic performance and reliability analytics,” Prog. Photovoltaics Res. Appl., vol. 29, no. 2, pp. 143–158, 2021, doi: 10.1002/pip.3349.
[8] S. Lindig, A. Louwen, D. Moser, and M. Topic, “Outdoor pv system monitoring—input data quality, data imputation and filtering approaches,” Energies, vol. 13, no. 19, pp. 1–18, 2020, doi: 10.3390/en13195099.
[9] J. C. Teo, R. H. G. Tan, V. H. Mok, V. K. Ramachandaramurthy, and C. Tan, “Impact of partial shading on the p-v characteristics and the maximum power of a photovoltaic string,” Energies, vol. 11, no. 7, 2018, doi: 10.3390/en11071860.
[10] X. H. Nguyen, “Matlab/simulink based modeling to study effect of partial shadow on solar photovoltaic array,” Environ. Syst. Res., vol. 4, no. 1, pp. 1–10, 2015, doi: 10.1186/s40068-015-0042-1.
[11] A. Aronescu and J. Appelbaum, “The effect of collector azimuth on inter-row shading in photovoltaic fields—a comprehensive point of view,” Energies, vol. 16, no. 13, 2023, doi: 10.3390/en16134876.
[12] A. Al-Quraan, M. Al-Mahmodi, K. Alzaareer, C. El-Bayeh, and U. Eicker, “Minimizing the utilized area of pv systems by generating the optimal inter-row spacing factor,” Sustain., vol. 14, no. 10, 2022, doi: 10.3390/su14106077.
[13] O. Tsafarakis, K. Sinapis, and W. G. J. H. M. Van Sark, “A time-series data analysis methodology for effective monitoring of partially shaded photovoltaic systems,” Energies, vol. 12, no. 9, 2019, doi: 10.3390/en12091722.
[14] S. Ghosh, J. N. Roy, and C. Chakraborty, “A model to determine soiling, shading and thermal losses from pv yield data,” Clean Energy, vol. 6, no. 2, pp. 1137–1156, 2022, doi: 10.1093/ce/zkac014.
[15] N. Anani and H. Ibrahim, “Adjusting the single-diode model parameters of a photovoltaic module with irradiance and temperature,” Energies, vol. 13, no. 12, pp. 1–17, 2020, doi: 10.3390/en13123226.
[16] M. K. Al-Smadi, Y. Mahmoud, and W. Xiao, “A fast and accurate approach for power losses quantification of photovoltaic power systems under partial-shading conditions,” IET Renew. Power Gener., vol. 15, no. 5, pp. 939–951, 2021, doi: 10.1049/rpg2.12032.
[17] P. Guerriero, L. Piegari, R. Rizzo, and S. Daliento, “Mismatch based diagnosis of pv fields relying on monitored string currents,” Int. J. Photoenergy, vol. 2017, no. 2, 2017, doi: 10.1155/2017/2834685.
[18] L. Deville, M. Theristis, B. H. King, T. L. Chambers, and J. S. Stein, “Open-source photovoltaic model pipeline validation against well-characterized system data,” Prog. Photovoltaics Res. Appl., vol. 32, no. 5, pp. 291–303, 2024, doi: 10.1002/pip.3763.
[19] T. Betti, A. Kristić, I. Marasović, and V. Pekić, “Accuracy of simscape solar cell block for modeling a partially shaded photovoltaic module,” Energies , vol. 17, no. 10, 2024, doi: 10.3390/en17102276.
Refbacks
- There are currently no refbacks.